Report ID: 24112213 / Buyer |
Prepared for Exclusive Use by: |
Home Buyer |
Address of Property: |
123 Sample Report Dr Alpharetta GA 30022 |
Date of Service: |
11/22/2024 |
![]() |
Company Providing Service: |
Chris Williamson ASHI # 266745 |
Capstone MHT Dev, Inc dba HouseMaster |
108 Stonewood Trail Ball Ground GA 30107 |
(c) Copyright 2001 - 2025 HouseMaster | Services provided by a locally owned and independently operated franchise company. |
![]() |
![]() |
Report ID: 24112213 / Buyer |
(c) Copyright 2001 - 2025 HouseMaster | Services performed by a locally owned and independently operated franchise company. |
|
|||||
INSPECTION INFORMATION | ||||||||||||||||
|
|
INSPECTION DETAILS | |||||||||||
|
INTRODUCTION |
The purpose of this
report is to render the inspector's professional opinion of the
condition of the inspected elements of the referenced property
(dwelling or house) on the date of inspection. Such opinions are
rendered based on the findings of a standard limited time/scope
home inspection performed according to the Terms and Conditions of
the Inspection Order Agreement and in a manner consistent with
applicable home inspection industry standards. The inspection was
limited to the specified, readily visible and accessible installed
major structural, mechanical and electrical elements (systems and
components) of the house. The inspection does not represent a
technically exhaustive evaluation and does not include any
engineering, geological, design, environmental, biological,
health-related or code compliance evaluations of the house or
property. Furthermore, no representations are made with respect to
any concealed, latent or future conditions.
|
The GENERAL
INSPECTION LIMITATIONS on the following page provides information
regarding home inspections, including various limitations and
exclusions, as well as some specific information related to this
property. The information contained in this report was prepared
exclusively for the named Clients and is not transferable without
the expressed consent of the Company. The report, including all
Addenda, should be reviewed in its entirety.
|
REPORT TERMINOLOGY |
The following
terminology may be used to report conditions observed during the
inspection. Additional terms may also be used in the report:
|
SATISFACTORY
- Element was functional at the time of inspection. Element was
in working or operating order and its condition was at least
sufficient for its minimum required function, although routine
maintenance may be needed.
|
FAIR -
Element was functional at time of inspection but has a probability
of requiring repair, replacement or other remedial work at any time
due to its age, condition, lack of maintenance or other factors.
Have element regularly evaluated and anticipate the need to take
action.
|
POOR -
Element requires immediate repair, replacement, or other remedial
work, or requires evaluation and/or servicing by a qualified
specialist.
|
NOT APPLICABLE
- All or individual listed elements were not present, were not
observed, were outside the scope of the inspection, and/or were not
inspected due to other factors, stated or otherwise.
|
NOT INSPECTED
(NOT RATED) - Element was disconnected or de-energized, was not
readily visible or accessible, presented unusual or unsafe
conditions for inspection, was outside scope of the inspection,
and/or was not inspected due to other factors, stated or otherwise.
Independent inspection(s) may be required to evaluate element
conditions. If any condition limited accessibility or
otherwise impeded completion of aspects of the inspection,
including those listed under LIMITATIONS, it is recommended that
limiting factors be removed or eliminated and that an inspection of
these elements be arranged and completed prior to closing.
|
IMPORTANT
NOTE: All repair needs or recommendations for further evaluation
should be addressed prior to closing. It is the client’s
responsibility to perform a final inspection to determine the
conditions of the dwelling and property at the time of closing. If
any decision about the property or its purchase would be affected
by any condition or the cost of any required or discretionary
remedial work, further evaluation and/or contractor cost quotes
should be obtained prior to making any such
decisions.
|
NATURE OF THE FRANCHISE RELATIONSHIP |
The Inspection
Company ("Company") providing this inspection report is a
franchisee of HouseMaster SPV LLC ("Franchisor"). As a franchisee,
the Company is an independently owned and operated business that
has a license to use the HouseMaster names, marks, and certain
methods. In retaining the Company to perform inspection services,
the Client acknowledges that Franchisor does not control this
Company’s day-to-day activities, is not involved in
performing inspections or other services provided by the Company,
and is in no way responsible for the Company’s actions.
Questions on any issues or concerns should be directed to the
listed Company.
|
GENERAL INSPECTION LIMITATIONS |
CONSTRUCTION
REGULATIONS - Building codes and construction standards vary
regionally. A standard home inspection does not include
evaluation of a property for compliance with building or health
codes, zoning regulations or other local codes or ordinances. No
assessments are made regarding acceptability or approval of any
element or component by any agency, or compliance with any specific
code or standard. Codes are revised on a periodic basis;
consequently, existing structures generally do not meet current
code standards, nor is such compliance usually required. Any
questions regarding code compliance should be addressed to the
appropriate local officials.
|
HOME MAINTENANCE
- All homes require regular and preventive maintenance to
maximize the economic life spans of elements and to minimize
unanticipated repair or replacement needs. Annual maintenance costs
may run 1 to 3% (or more) of the sales price of a house depending
on age, design, and/or the degree of prior maintenance. Every
homeowner should develop a preventive maintenance program and
budget for normal maintenance and unexpected repair expenses.
Remedial work should be performed by a specialist in the
appropriate field following local requirements and best
practices.
|
ENVIRONMENTAL
AND MOLD ISSUES (AND EXCLUSIONS) - The potential health effects
from exposure to many elements found in building materials or in
the air, soil, water in and/or around any house are varied. A home
inspection does not include the detection, identification or
analysis of any such element or related concerns such as, but not
limited to, mold, allergens, radon, formaldehyde, asbestos, lead,
electromagnetic fields, carbon monoxide, insecticides,
refrigerants, and fuel oils. Furthermore, no evaluations are
performed to determine the effectiveness of any system designed to
prevent or remove any elements (e.g., water filters or radon
mitigation). An environmental health specialist should be contacted
for evaluation of any potential health or environmental concerns.
Review additional information on MOLD/MICROBIAL ELEMENTS
below.
|
AESTHETIC
CONSIDERATIONS - A standard building inspection does not
include a determination of all potential concerns or conditions
that may be present or occur in the future including
aesthetic/cosmetic considerations or issues (appearances, surface
flaws, finishes, furnishings, odors, etc.).
|
DESIGN AND
ADEQUACY ISSUES - A standard home inspection does not
include any element design or adequacy evaluations including
seismic or high-wind concerns, soil bearing, energy efficiencies,
or energy conservation measures. It also does not address in any
way the function or suitability of floor plans or other design
features. Furthermore, no determinations are made regarding product
defects notices, safety recalls, or other similar manufacturer or
public/private agency warnings related to any material or element
that may be present in any house or on any property.
|
AGE ESTIMATIONS
AND DESIGN LIFE RANGES - Any age estimations represent the
inspector's opinion as to the approximate age of components.
Estimations may be based on numerous factors including, but not
limited to, appearance and owner comment. Design life ranges
represent the typical economic service life for elements of similar
design, quality and type, as measured from the time of original
construction or installation. Design life ranges do not take into
consideration abnormal, unknown, or discretionary factors, and are
not a prediction of future service life. Stated age or
design life ranges are given in "years," unless otherwise noted,
and are provided for general guidance purposes only. Obtain
independent verification if knowledge of the specific age or future
life of any element is desired or required.
|
ELEMENT
DESCRIPTIONS - Any descriptions or representations of element
material, type, design, size, dimensions, etc., are based primarily
on visual observation of inspected or representative components.
Owner comment, element labeling, listing data, and rudimentary
measurements may also be considered in an effort to describe an
element. However, there is no guarantee of the accuracy of any
material or product descriptions listed in this report; other or
additional materials may be present. Independent evaluations and/or
testing should be arranged if verification of any element's makeup,
design, or dimension is needed. Any questions arising from the use
of any particular terminology or nomenclature in this report
should be addressed prior to closing.
|
REMEDIAL WORK
- Quotes should be obtained prior to closing from qualified
(knowledgeable and licensed as required) specialists/contractors to
determine actual repair/replacement costs for any element or
condition requiring attention. Any cost estimates provided with a
home inspection, whether oral or written, only represent an
approximation of possible costs. Cost estimates do not reflect all
possible remedial needs or costs for the property; latent concerns
or consequential damage may exist. If the need for remedial work
develops or is uncovered after the inspection, prior to performing
any repairs contact the Inspection Company to arrange a
re-inspection to assess conditions Aside from basic maintenance
suitable for the average homeowner, all repairs or other remedial
work should be performed by a specialist in the appropriate field
following local requirements and best practices.
|
SELLER
DISCLOSURE - This report is not a substitute for Seller
Disclosure. A Property History Questionnaire form may be
provided with this report to help obtain background information on
the property in the event a full Seller Disclosure form is not
available. The buyer should review this form and/or the Seller
Disclosure with the owner prior to closing for clarification or
resolution of any questionable items. A final buyer inspection of
the house (prior to or at the time of closing) is also
recommended.
|
WOOD-DESTROYING
INSECTS/ORGANISMS - In areas subject to wood-destroying insect
activity, it is advisable to obtain a current wood-destroying
insect and organism report on the property from a qualified
specialist, whether or not it is required by a lender. A standard
home inspection does not include evaluation of the nature or
status of any insect infestation, treatment, or hidden damage, nor
does it cover issues related to other house pests or nuisances or
subsequent damage.
|
ELEMENTS NOT
INSPECTED - Any element or component not evaluated as part of
this inspection should be inspected prior to closing. Either make
arrangements with the appropriate tradesman or contact the
Inspection Company to arrange an inspection when all elements are
ready for inspection.
|
HOUSE
ORIENTATION - Location descriptions/references are provided for
general guidance only and represent orientations based on a view
facing the front of the house from the outside. Any references
using compass bearings are only approximations. If there are any
questions, obtain clarification prior to closing.
|
CONDOMINIUMS
- The Inspection of condominium/cooperative do not include
exteriors/ typical common elements, unless otherwise noted. Contact
the association/management for information on common element
conditions, deeds, and maintenance responsibilities.
|
MOLD AND MICROBIAL ELEMENTS / EXCLUSIONS |
The purpose and
scope of a standard home inspection does not include the
detection, identification or assessment of fungi and other
biological contaminants, such as molds, mildew, wood-destroying
fungi (decay), bacteria, viruses, pollens, animal dander, pet or
vermin excretions, dust mites and other insects. These elements
contain/carry microbial particles that can be allergenic,
infectious or toxic to humans, especially individuals with asthma
and other respiratory conditions or sensitivity to chemical or
biological contaminants. Wood-destroying fungi, some molds, and
other contaminants can also cause property damage. One particular
biological contamination concern is mold. Molds are present
everywhere. Any type of water leakage, moisture condition or
moisture-related damage that exists over a period of time can lead
to the growth of potentially harmful mold(s). The longer the
condition(s) exists, the greater the probability of mold growth.
There are many different types of molds; most molds do not create a
health hazard, but others are toxic.
|
Indoor mold
represents the greatest concern as it can affect air quality and
the health of individuals exposed to it. Mold can be found in
almost all homes. Factors such as the type of construction
materials and methods, occupant lifestyles, and the amount of
attention given to house maintenance also contribute to the
potential for molds. Indoor mold contamination begins when spores
produced by mold spread by air movement or other means to an area
conducive to mold growth. Mold spores can be found in the air,
carpeting, insulation, walls and ceilings of all buildings. But
mold spores only develop into an active mold growth when exposed to
moisture. The sources of moisture in a house are numerous and
include water leakage or seepage from plumbing fixtures,
appliances, roof openings, construction defects (e.g., EIFS wall
coverings or missing flashing) and natural catastrophes like floods
or hurricanes. Excessive humidity or condensation caused by faulty
fuel-burning equipment, improper venting systems, and/or inadequate
ventilation provisions are other sources of indoor moisture. By
controlling leakage, humidity and indoor air quality, the potential
for mold contamination can be reduced. To prevent the spread of
mold, immediate remediation of any water leakage or moisture
problems is critical. For information on mold testing or
assessments, contact a qualified mold specialist.
|
Neither the
evaluation of the presence or potential for mold growth, nor the
identification of specific molds and their effects, fall within the
scope of a standard home inspection. Accordingly, the Inspection
Company assumes no responsibility or liability related to the
discovery or presence of any molds, their removal, or the
consequences whether property or health-related.
|
ADDITIONAL COMMENTS |
If any area of the home is inaccessible and/or elements were concealed or otherwise obstructed from the view, then an inspection of that area/element could not be performed. The seller should be questioned about any concerns that may exist related to inaccessible or hidden areas prior to closing. If possible, access should be provided or limiting factors should be removed to allow an inspection prior to closing by the home inspector or appropriate specialist. Any pictures (photographs, graphics, or images) included in or otherwise provided in conjunction with this Inspection Report generally portray overviews of certain elements, depict specific conditions or defects described in the report, or are used solely for orientation purposes. These pictures do not necessarily reflect all conditions or issues that may need attention or otherwise be of concern. Neither the inclusion of any picture in the report nor the exclusion of any picture taken during the inspection from the Report is intended to highlight or diminish the significance or severity of any defect or condition, except as may be described in the Inspection Report. Furthermore, the lack of a picture for any element or condition also does not change the significance or severity of any defect or condition described in the Inspection Report. The Report must be read in its entirety for all pertinent information. Additional pictures which may have been taken but were not provided with the report are the property of the company and are maintained for a limited time for reference purposes only. Numerous devices in homes today are operated with remote controls. Assessment of these controls/devices is not within the scope of a standard home inspection. For a list of and information about these devices, contact the seller. Some of these devices have changeable codes that should be reset for your use or safety. Refer to the manufacturer instructions for further information and warnings. Due to seasonal factors or weather conditions, evaluation of some elements may have been severely restricted or not possible. Client should assess the level of concern that may exist due to such limitations and arrange additional inspections when conditions permit or otherwise address limitations prior to closing. If there are any questions on the need for further inspections or other work, contact the local HouseMaster office. Please review this report closely to determine if any item or component was not inspected due to incomplete work, unconnected or shutdown utilities, or other factors; arrange for an inspection of these components prior to closing. Many insurance companies now mandate insurance inspections or otherwise assess a home’s condition to determine whether it meets their particular criteria or regulatory requirements for homeowner insurance coverage. These inspections or assessments may not be performed until after the home has been purchased. Each jurisdiction and insurance company has varying underwriting requirements. This home inspection was not performed to determine whether the dwelling or property meets the applicable governmental agencies or any particular insurance company’s underwriting requirements. It is recommended that all home buyers consult with their insurance agent/provider prior to the purchase of the home to determine any underwriting requirements or limitations that might affect their ability to obtain insurance or premiums. It is often not possible to properly evaluate certain elements in a new structure or if a house has been vacant for any length of time. For example, a drain leak in a wall or blockage in an underground waste line may not become apparent until hours (or days) after the inspection. Therefore, anticipate the possibility of such latent defects with subsequent use of the house and/or systems. Furthermore, a thorough pre-closing inspection is recommended. Pictures in Report - Any pictures (photographs, graphics, or images) included in or otherwise provided in conjunction with this Inspection Report generally portray overviews of certain elements, depict specific conditions or defects described in the report, or are used solely for orientation purposes. These pictures do not necessarily reflect all conditions or issues that may need attention or otherwise be of concern. Neither the inclusion of any picture in the report nor the exclusion of any picture taken during the inspection from the Report is intended to highlight or diminish the significance or severity of any defect or condition, except as may be described in the Inspection Report. Furthermore, the lack of a picture for any element or condition also does not change the significance or severity of any defect or condition described in the Inspection Report. The Report must be read in its entirety for all pertinent information. Additional pictures which may have been taken but were not provided with the report are the property of the company and are maintained for a limited time for reference purposes only. Product Notices - A standard home inspection does not include identification or research regarding products (appliances, piping, roofing, or other building components) installed in a home that may be the subject of a defect study, investigation, warning or recall notice issued by a manufacturer, the Consumer Product Safety Commission (CPSC), or any other entity. It is very difficult, if not impossible in many cases, to determine which items in a house may be the subject of an investigation or notice. Should this report include any reference to a product notice, it is provided for general guidance purposes only and does not imply that an inspection or research was performed to identify other possible concerns. As you take on ownership of your home it is recommended that you visit the Consumer Product Safety Commission (www.cpsc.gov ) or Canadian Standards Association (www.csa.ca) web sites for current information on any recalls and safety notices that may be associated with the materials or equipment in your home. |
(c) Copyright 2001 - 2025 HouseMaster
|
Each HouseMaster
Franchise is an Independently Owned and Operated Business.
|
![]() |
![]() Report ID: 24112213 / Buyer |
![]() |
![]() |
![]() |
![]() |
PORCHES/DECKS: Covered Porch w/ Wood Floor Front of House Wood Frame Deck w/ Wood Flooring Rear of House |
SPECIAL LIMITATIONS: Leaves/debris |
SIDING 1: Style: Lapped Material: Hardboard/Fiberboard Location: Whole House |
SIDING 2: Style: Lapped Material: Fibercrete Location: Chimney Location: Repaired areas |
S | F | P | NA | NI | ||
![]() |
1.0 | SIDING 1 Hardboard siding noted. This type siding is subject to deterioration from water intrusion. Keep all cut ends
sealed and painted. If delamination or water absorption is present or presents in the future, anticipate
replacement of damaged areas.
|
||||
![]() |
1.1 | SIDING 2 Noted damage near the gutter union at rear and hole at chimney; repair as needed See note 3.2 and
13.0
|
||||
![]() |
1.2 | WINDOWS The evaluation of windows is based on a limited inspection of representative, readily accessible units.
Varying conditions may be found at other units. Review the Interior Section for additional information on
window conditions.
|
||||
![]() |
1.3 | ENTRY DOORS Entries not protected with a roof often leak at the rim joints and threshold surrounding the doorway during
certain weather conditions. Check these joints regularly and caulk and seal as necessary. Chronic leaks
can cause wood decay at the trim above the door and the bandboard / joists below the threshold.
Concrete patio slabs can also move because of frost action, creating a gap at the door threshold and
possible wood decay. Monitor and seal as needed. Adding storm doors may help, but an extended roof
always provides the best protection against the elements.
|
||||
![]() |
1.4 | STAIRS / STOOPS Noted deck stair stringers are not supported as recommended in DCA 6 (sloped hangers). The DCA 6
support recommendation is not commonly installed and alternative methods can function well. Monitor the
stairs for indications of failure such as splitting wood and defection and repair as needed.Noted some
cracking at stringers as well; monitor and repair as needed.
Noted stairs are in contact with the ground, this can cause deterioration and attract wood destroying organisms; repair as needed. |
||||
![]() |
1.5 | Front Porch(es) Noted wood underpinning is in contact with ground at front of home. This can cause deterioration and
attract wood-destroying insects.
The porch appears nailed to the house. Generally older decks do not meet today's standards for posts / joists dimensions, as well as, requirements for joists hangers, lateral bracing, nailing patterns and bolting / strapping deck to home. The codes are not retroactive. However, we recommend consulting with a qualified contractor for remedial needs and costs |
||||
![]() |
1.6 | DECK(S) The deck appears to be nailed to the house with no other visible means of attachment. Nails can
corrode or pull out, causing the deck to collapse. Concealed damage to framing and/or siding behind
the deck can also result in deck collapse. Have the deck attachment investigated by a licensed general
contractor or professional engineer. Unless it can be demonstrated that the deck is properly and solidly
fastened to the house, the deck should be bolted to the house or otherwise be repair as needed.
Noted the absence of flashing between the deck and house. The house/deck joint generally needs a
flashing to prevent water seepage and framing damage that could affect structural integrity. No joist support is present at rim area and joists are showing signs of defection. Generally older decks do not meet today's standards for posts / joists dimensions, as well as, requirements for joists hangers, lateral bracing, nailing patterns and bolting / strapping deck to home. The codes are not retroactive. However, we recommend consulting with a qualified contractor for remedial needs and costs |
||||
![]() |
1.7 | RAILINGS Although not required when the house was built, current codes prohibit notching or toe nailing of rail
posts; monitor and repair as needed for safety. Guardrails should be able to withstand 200 pounds per
square foot in any direction at any point along the top.
Handrails are required along the stairway. They must be graspable (non-circular max cross section is 2 1/4") and securely fastened to the wall and/or supports. The flat boards used are not graspable in case of tripping and falling; repair as needed for safety. Handrails need to be secure and positioned at the correct height and with suitable spacing between spindles or balusters (a 4-inch maximum spacing is now the standard). |
||||
![]() |
1.8 | FOUNDATION COATING | ||||
![]() |
1.9 | ELECTRIC / GFCI(S) No GFCI protection is present at the front porch receptacle; add as needed.
Exterior lighting is generally randomly checked to assess basic wiring conditions. Any inoperative unit may be due to a defective fixture or bulb, connection to undetected switch, timer/sensor or other factors. |
||||
![]() |
1.10 | EXTERIOR FAUCET(S) Noted rear facuet is shut off. Exterior faucets that do not operate may be turned off, not connected, or, in
cold weather, may be frozen. Consider all factors when concerns are indicated. The use of backflow
preventers is advised, and in many areas now required, to prevent possible contamination of the water
supply condition.
|
||||
![]() |
1.11 | TREES/BUSHES/IVY The vegetation should be kept cleared to allow a 24" clearance around the structure.
|
||||
S | F | P | NA | NI | S= Satisfactory, F= Fair, P= Poor, NA= Not Applicable, NI= Not Inspected |
![]() 1.0 SIDING 1 (Picture 1) delamination
|
![]() 1.1 SIDING 2 (Picture 1) hole at chimney
|
![]() 1.3 ENTRY DOORS (Picture 1) uncovered entry
|
![]() 1.4 STAIRS / STOOPS (Picture 1) ground contact
|
![]() 1.4 STAIRS / STOOPS (Picture 2) no hangers
|
![]() 1.4 STAIRS / STOOPS (Picture 3) splitting
|
![]() 1.5 Front Porch(es) (Picture 1) wood/ground contact
|
![]() 1.5 Front Porch(es) (Picture 2) nailed to house
|
![]() 1.6 DECK(S) (Picture 1) nailed to house/no flashing
|
![]() 1.6 DECK(S) (Picture 2) no joist support
|
![]() 1.6 DECK(S) (Picture 3) separation
|
![]() 1.6 DECK(S) (Picture 4) ground contact
|
![]() 1.6 DECK(S) (Picture 5) debris
|
![]() 1.7 RAILINGS (Picture 1) spacing
|
![]() 1.9 ELECTRIC / GFCI(S) (Picture 1) no GFCI protection
|
![]() 1.9 ELECTRIC / GFCI(S) (Picture 2) check bulb
|
![]() 1.10 EXTERIOR FAUCET(S) (Picture 1) turned off
|
(c) Copyright 2001 - 2025 HouseMaster | Each HouseMaster Franchise is an Independently Owned and Operated Business. |
![]() |
![]() Report ID: 24112213 / Buyer |
WALKWAYS/DRIVEWAYS: Walks: Concrete Driveway: Concrete Driveway: Stone |
RETAINING WALLS: Type: Cinder blocks Location: Right Side of House |
S | F | P | NA | NI | ||
![]() |
2.0 | DRIVEWAY Exception noted of settlement cracking; recommend sealing cracks to prevent water penetration and
freeze thaw expansion. Replacement of damaged areas will be required if there is any significant
displacement or damage.
|
||||
![]() |
2.1 | WALKWAYS Exception noted of settlement cracking; recommend sealing cracks to prevent water penetration and
freeze thaw expansion. Some areas of cracking and lifting may pose a-trip hazard; repair as required.
Debris cover at some areas; check as needed. |
||||
![]() |
2.2 | RETAINING WALL(S) Loose/leaning blocks noted at driveway/garage area; repair as needed.
Inspection of any retaining wall is
limited to evaluation of its potential affect on the building, unless otherwise noted. Walls must be checked
and maintained periodically. Drainage provisions may need to be cleaned or added if evidence of lateral
movement is present.
|
||||
![]() |
2.3 | GROUND SLOPE AT FOUNDATION Depression and backsloped areas noted at various points around the foundation. Correct grading and
drainage; also add ground cover where needed.
|
||||
![]() |
2.4 | SITE GRADING Grading slopes towards the house in several areas; assess run-off features and correct as needed.
|
||||
![]() |
2.5 | LAWN SPRINKLER Several pipes for irrigation system. The panel appears older and shut down.
|
||||
S | F | P | NA | NI | S= Satisfactory, F= Fair, P= Poor, NA= Not Applicable, NI= Not Inspected |
![]() 2.0 DRIVEWAY (Picture 1) cracking
|
![]() 2.1 WALKWAYS (Picture 1) possible trip hazard
|
![]() 2.1 WALKWAYS (Picture 2) clear debris
|
![]() 2.2 RETAINING WALL(S) (Picture 1) leaning block
|
![]() 2.4 SITE GRADING (Picture 1) sloped toward house
|
![]() 2.5 LAWN SPRINKLER (Picture 1) older panel
|
(c) Copyright 2001 - 2025 HouseMaster | Each HouseMaster Franchise is an Independently Owned and Operated Business. |
![]() |
![]() Report ID: 24112213 / Buyer |
![]() |
![]() |
![]() |
![]() |
![]() |
ROOF STYLE: Mixed Slope |
MATERIAL: 3 Tab Asphalt |
ESTIMATED AGE: 10 to 15 Years |
DESIGN LIFE: 15 to 20 years |
INSPECTION METHOD: Walked On |
CHIMNEYS/VENTS: Metal Chimney w/ Enclosure |
S | F | P | NA | NI | ||
![]() |
3.0 | ROOF COVERING The roof appears to have wind damage or other manufacturer defects. Several of the shingles are loose
when spot checked. Have a qualified roofer determine the extend of damage and professional opinion for
remediation.
Noted missing drip edge flashing in areas. Although perhaps not required when the home was built, a drip edge helps to prevent leakage, premature shingle wear and wood deterioration at eaves. Monitor and repair as needed. |
||||
![]() |
3.1 | EXPOSED FLASHING Noted missing kickout flashing and gutter clearance at siding unions. Cement manufactures typically
advise a gap at siding and gutter unions with kickout flashing to direct the water to the gutter; repair as
needed. Kick out flashing diverts water away from the siding and fascia. It can prevent moisture related
problems where water may get behind siding and cause consequential damage.
|
||||
![]() |
3.2 | PLUMBING STACKS
Noted several boot flashing have been tarred over and one boot cover is depressed which will not allow
water to run off. Anticipate the need to replace roof flashing/coverings at next roof ing or if leakage
occurs. All vent pipe flashings should be checked periodically and should be repaired and/or sealed as
needed.
|
||||
![]() |
3.3 | SKYLIGHT(S)
Skylights are particularly prone to leakage and may need periodic repair and or resealing. The integrity of
the flashings is generally the first point to consider when leakage occurs. Surface damage or loss of the
seal on insulated glazing can occur, but such a defect may not be readily apparent during an inspection.
|
||||
![]() |
3.4 | RAIN GUTTERS / EAVESTROUGHS
All gutters should be checked for damage, blockage, or overflow on a regular basis (at least twice
annually).
|
||||
![]() |
3.5 | DOWNSPOUTS / ROOF DRAINS
To minimize water ponding at the foundation and the potential for interior water penetration, downspout
extensions or splash blocks should be utilized at the termination points of all downspouts/roof drains.
Downspout discharge onto lower roofs can cause leakage/premature wear. This condition should be monitored or corrected to ensure that no consequential damage occurs. |
||||
![]() |
3.6 | FASCIA / SOFFITS Loose soffit vent at front porch; repair as needed. Metal repairs noted around the eave areas indicating
rodent inclusion work; check with seller regarding history of activity and any potential warranties for
inclusion work.
|
||||
![]() |
3.7 | CHIMNEY The chimney cap is in place; no interior evaluation was possible. Have cleaned/checked as a precaution.
Noted rust at chimney chase cover; recommend prepping and painting with an exterior paint. |
||||
S | F | P | NA | NI | S= Satisfactory, F= Fair, P= Poor, NA= Not Applicable, NI= Not Inspected |
![]() 3.0 ROOF COVERING (Picture 1) lifting shingles
|
![]() 3.0 ROOF COVERING (Picture 2) loose shingle
|
![]() 3.0 ROOF COVERING (Picture 3) loose shingle
|
![]() 3.0 ROOF COVERING (Picture 4) loose shingle
|
![]() 3.0 ROOF COVERING (Picture 5) loose shingle
|
![]() 3.0 ROOF COVERING (Picture 6) loose shingle
|
![]() 3.1 EXPOSED FLASHING (Picture 1) no kickout flashing/clearance
|
![]() 3.2 PLUMBING STACKS (Picture 1) tar at vent boot
|
![]() 3.2 PLUMBING STACKS (Picture 2) tar
|
![]() 3.2 PLUMBING STACKS (Picture 3) tar
|
![]() 3.2 PLUMBING STACKS (Picture 4) depressed boot
|
![]() 3.6 FASCIA / SOFFITS (Picture 1) loose vent
|
![]() 3.6 FASCIA / SOFFITS (Picture 2) repairs
|
![]() 3.6 FASCIA / SOFFITS (Picture 3) repairs
|
![]() 3.7 CHIMNEY (Picture 1) rust
|
(c) Copyright 2001 - 2025 HouseMaster | Each HouseMaster Franchise is an Independently Owned and Operated Business. |
![]() |
![]() Report ID: 24112213 / Buyer |
GARAGE DESCRIPTION: Type: Under House Type: Two Car Construction: Wood Frame Finish at House: Drywall on Wall Door at House: Solid door |
S | F | P | NA | NI | ||
![]() |
4.0 | EXPOSED FRAMING Noted metal column not anchored to slab; repair as needed. A few of the joists are showing signs of minor
splitting; monitor and repair as needed. The stud support for the main beam at the outer garage wall is
leaning/crooked; recommend bracing as needed.
|
||||
![]() |
4.1 | FLOOR SLAB Exception noted of settlement cracking, monitor and repair as needed. Traditionally slabs are non-structural, although no engineering analysis performed on slab.
|
||||
![]() |
4.2 | FOUNDATION Settlement noted. This is typical of older construction; however, no engineering evaluation was performed
to confirm acceptability of conditions.
|
||||
![]() |
4.3 | WALLS / CEILINGS Evidence of suspect mold is present at the rear wall behind the laundry room. No mold assessment or
inspection was performed. Chronic water leakage/seepage may promote the growth of mold and mildew.
Some mold/mildew spores can be harmful. Any potential mold or mildew conditions should be addressed
immediately. A certified technician/laboratory can sample and analyze air quality and suspect mold
conditions to determine the nature of the contamination and corrective measures that may be needed,
repair as appropriate. Arrangements can be made with our office for surface and/or bulk air sampling.
|
||||
![]() |
4.4 | VEHICLE DOOR(S) No safety cables were observed inside the springs. Damaged tracks, springs and cables may cause door
operation malfunction but also represent potential safety hazards. A qualified specialist should inspect and
repair any defective or missing components.
|
||||
![]() |
4.5 | DOOR OPERATOR(S) Electric-eye style sensor is in place, but appear high. Typically 6 inches from the floor. Check
manufacture specifications and correct as needed. Door reversed with limited assessment with
obstruction; however, the door and operator should be checked at occupancy and regularly for proper
function.
No operator present at one door; add as needed or desired. The doors opened and closed satisfactory with manual operation. |
||||
![]() |
4.6 | ELECTRIC / GFCI Most receptacles are not GFCI protected; add GFCI protection for safety.
|
||||
![]() |
4.7 | HOUSE / SERVICE DOOR(S) Missing or damaged weather stripping was noted. Weather stripping at exterior doors minimizes air
infiltration that can adversely impact the homes efficiency. The condition can also allow insect or pest
entry to the home. Replace missing or damaged weather stripping where needed.
|
||||
S | F | P | NA | NI | S= Satisfactory, F= Fair, P= Poor, NA= Not Applicable, NI= Not Inspected |
![]() 4.0 EXPOSED FRAMING (Picture 1) splitting
|
![]() 4.0 EXPOSED FRAMING (Picture 2) not anchored
|
![]() 4.0 EXPOSED FRAMING (Picture 3) leaning studs
|
![]() 4.3 WALLS / CEILINGS (Picture 1) potential mold
|
![]() 4.4 VEHICLE DOOR(S) (Picture 1) no safety cables
|
![]() 4.5 DOOR OPERATOR(S) (Picture 1) eye sensors high
|
![]() 4.6 ELECTRIC / GFCI (Picture 1) no GFCI protection
|
![]() 4.7 HOUSE / SERVICE DOOR(S) (Picture 1) no weather stripping
|
(c) Copyright 2001 - 2025 HouseMaster | Each HouseMaster Franchise is an Independently Owned and Operated Business. |
![]() |
![]() Report ID: 24112213 / Buyer |
![]() |
![]() |
ATTIC: Style: Exposed Framing Entrance: Scuttle Hatch Insp. Method: From Entrance Area |
ROOF CONSTRUCTION: Framing: Wood Trusses Deck: OSB Sheathing |
INSULATION: Form: Blown-in Type: Fiberglass Est. Average: 2 to 4 Inches |
VENTILATION PROVISIONS: Location: Ridge and Soffits Powered: Attic Exhaust Fan w/ Thermostatic Control |
SPECIAL LIMITATIONS: No Walkway Design Insulation Over Faming Inaccessible areas |
S | F | P | NA | NI | ||
![]() |
5.0 | ROOF FRAMING Access over the common areas is nailed or otherwise secured shut and could not be inspected.
|
||||
![]() |
5.1 | ROOF DECK / SHEATHING Noted not all areas could be observed due to limited access, attic design and other limitations; monitor
and repair as needed.
|
||||
![]() |
5.2 | VENTILATION PROVISIONS Check the attic temperature on a hot day. If the attic temperature is more than 15-20 degrees above the
full sun outside temperature, additional ventilation is recommended. For every square foot of attic floor
space there should be one square inch of attic ventilation opening at roof, gables or soffits. The
preceding can be accomplished by several different means; static roof vents, ridge vents, soffit or gable
vents. Ideally 50% of the ventilation should be close to or at the roof peak and 50% at the soffit area.
|
||||
![]() |
5.3 | ATTIC VENTILATOR(S) Thermostatically controlled vent fan mounted in roof was not inspected due to low temperature. The fans
should be shut down as it will only compete with the new ridge venting.
|
||||
![]() |
5.4 | INSULATION Insulation is below current recommended/required level and should be improved. Today's standard is
typically 10-12 inches for this region.
|
||||
![]() |
5.5 | RODENT ACTIVITY Noted possible droppings in attic; recommend contacting a qualified pest control company for remedial
needs and costs prior to closing.
|
||||
![]() |
5.6 | CEILING HATCH Recommend adding block insulation to ceiling hatch for reduced energy loss and a barrier around
opening to prevent insulation from falling out.
|
||||
S | F | P | NA | NI | S= Satisfactory, F= Fair, P= Poor, NA= Not Applicable, NI= Not Inspected |
![]() 5.6 CEILING HATCH (Picture 1) ceiling hatch
|
![]() 5.6 CEILING HATCH (Picture 2) normal view
|
![]() 5.6 CEILING HATCH (Picture 3) wall hatch
|
![]() 5.6 CEILING HATCH (Picture 4) normal view
|
(c) Copyright 2001 - 2025 HouseMaster | Each HouseMaster Franchise is an Independently Owned and Operated Business. |
![]() |
![]() Report ID: 24112213 / Buyer |
![]() bathroom 1 |
![]() master bathroom |
BATHROOM 1: Type: Full Location: First Floor Hall Ventilation: Ceiling Exhaust Fan |
BATHROOM 2: Type: Three-Quarter Location: Master Bedroom Ventilation: Window Only |
S | F | P | NA | NI | ||
![]() |
6.0 | HALL BATHROOM 1 | ||||
![]() |
6.1 | SINK(S) Noted leaking drain; repair as needed.
|
||||
![]() |
6.2 | TOILET Leaking noted at the drain coupling in the garage. Recommend conditions be evaluated by a licensed
plumber to determine remedial action required and associated costs.
|
||||
![]() |
6.3 | BATHTUB
Operation of the bathtub/shower diverter does not direct full water flow to the showerhead. Repair or
replacement may be required to provide full flow. The original drain plug is missing; repair as needed.
|
||||
![]() |
6.4 | FLOOR(ING) | ||||
![]() |
6.5 | WALLS / CEILING | ||||
![]() |
6.6 | VENTILATOR
The bathroom exhaust fan should discharge directly to the exterior to prevent excess moisture concerns in
the house or attic area. Recommend extending the duct to a suitable discharge point or correcting the
current arrangement as conditions warrant.
|
||||
![]() |
6.7 | ELECTRIC / GFCI | ||||
![]() |
6.8 | MASTER BATHROOM | ||||
![]() |
6.9 | SINK(S) S-type drain traps and other older designs are obsolete; have checked by a plumber to determine current
function. Correct now if problems are identified; otherwise plan to upgrade when drain repairs or
renovation work is performed. A p- trap should be located no more than 24 inches vertically from the
fixture outlet by todays plumbing standards.
|
||||
![]() |
6.10 | TOILET Toilet is loose at the floor; check for leakage/damage and secure as required. The wax ring inside the unit
must have a snug, secure fit in order to keep from leaking. This type of damage is not always visible or
accessible to the inspector at time of inspection. Recommend further evaluation/correction by a licensed
plumber.
|
||||
![]() |
6.11 | STALL SHOWER | ||||
![]() |
6.12 | SURROUNDS / ENCLOSURES Caulking and/or grouting work is required to maintain the watertightness of tile and the tub/shower
enclosures. Check for substrate damage if surface damage or leakage is present, and when performing
regular maintenance.
|
||||
![]() |
6.13 | FLOOR(ING) | ||||
![]() |
6.14 | WALLS / CEILING | ||||
![]() |
6.15 | VENTILATOR No vent was present. If excessive moisture/mildew buildup in the bathroom area presents or is present, it
may be indicative of inadequate ventilation provisions, insulation/vapor retarder concerns or other
conditions. Correct to prevent consequential damage. While a window is provided for the room,
mechanical ventilation may also be needed to prevent moisture buildup.
|
||||
![]() |
6.16 | ELECTRIC / GFCI | ||||
S | F | P | NA | NI | S= Satisfactory, F= Fair, P= Poor, NA= Not Applicable, NI= Not Inspected |
![]() 6.1 SINK(S) (Picture 1) leaking
|
![]() 6.3 BATHTUB (Picture 1) diverter worn
|
![]() 6.9 SINK(S) (Picture 1) s-trap
|
![]() 6.10 TOILET (Picture 1) loose toilet
|
(c) Copyright 2001 - 2025 HouseMaster | Each HouseMaster Franchise is an Independently Owned and Operated Business. |
![]() |
![]() Report ID: 24112213 / Buyer |
![]() kitchen area |
![]() range operation |
![]() oven |
RANGE: Gas Range Est. Age: < 1 Year |
DISHWASHER: Est. Age: < 1 Year |
VENTILATOR: Recirculating |
S | F | P | NA | NI | ||
![]() |
7.0 | PLUMBING / SINK | ||||
![]() |
7.1 | FLOOR | ||||
![]() |
7.2 | WALLS / CEILING | ||||
![]() |
7.3 | ELECTRIC / GFCI No GFCI protection noted. Although not required when the home was built, GFCIs should have been
added when the kitchen was remodeled. Recommend consulting a qualified electrician for remedial needs
and costs.
|
||||
![]() |
7.4 | RANGE Range operated during inspection; however inspector cannot comment on effectiveness of its baking,
broiling or cleaning ability.
The oven does not appear to have proper tip-over protection. Check manufacturer instructions for information on provisions required. |
||||
![]() |
7.5 | DISHWASHER The dishwasher operated through one full cycle; however, neither the operation of all cycles or modes nor
its cleaning or drying ability was determined.
|
||||
![]() |
7.6 | DISPOSAL | ||||
![]() |
7.7 | VENTILATOR Bulb missing for vent; add as needed.
|
||||
![]() |
7.8 | CABINETRY | ||||
![]() |
7.9 | COUNTERTOP | ||||
S | F | P | NA | NI | S= Satisfactory, F= Fair, P= Poor, NA= Not Applicable, NI= Not Inspected |
![]() 7.7 VENTILATOR (Picture 1) missing bulb
|
IRC guidelines (M1503.4) states “Exhaust hood systems capable of exhausting in excess of 400 CFM shall be provided with make-up air at a rate approximately equal to the exhaust air rate. Such make-up air systems shall be equipped with a means of closure and shall be automatically controlled to start and operate simultaneously with the exhaust system.”
(c) Copyright 2001 - 2025 HouseMaster | Each HouseMaster Franchise is an Independently Owned and Operated Business. |
![]() |
![]() Report ID: 24112213 / Buyer |
![]() fireplace operation |
PREDOMINANT WALLS & CEILINGS: Wood Frame w/ Drywall |
PREDOMINANT FLOORS: Wood Frame |
PREDOMINANT WINDOWS: Double Hung w/Insulated Glass |
FIREPLACES/STOVES 1: Metal Fireplace w/ Gas Burner |
DETECTORS: Location: Hallways only Type: Smoke/Fire Detection |
S | F | P | NA | NI | ||
![]() |
8.0 | CEILINGS Exception noted of settlement cracking, repair as needed or desired
|
||||
![]() |
8.1 | WALLS Exception noted of settlement cracking, repair as needed or desired
|
||||
![]() |
8.2 | FLOORS (FRAMED) Slope at the floor can indicate movement or defection at portions of the floor framing. This condition is not
uncommon, particularly in older homes. While the condition often reflects movement that has subsided,
the potential for ongoing movement cannot be fully ruled out. Monitor for subsequent movement that may
indicate an ongoing structural concern and review notes in the Substructure Section. If continued
movement is suspected, evaluation by a Structural Engineer is advised along with recommendations
for repair or reinforcement where appropriate.
See also note 4.0 and 9.2 |
||||
![]() |
8.3 | STAIRS Stair tread/riser details must comply with standard construction practices to minimize trip hazards.
Irregular proportions/conditions should be corrected to provide normal dimensions.
|
||||
![]() |
8.4 | RAILINGS The handrail should return to the guard to prevent possible snags and injury; repair as needed.
|
||||
![]() |
8.5 | REPRESENTATIVE WINDOWS Noted window in dining room does not shut/lock properly; repair as needed.
Recommend taking an inventory of storms/screens to confirm desired coverage exists and/or storage locations. Any loose, damaged or missing storm windows or screens should be repaired as desired, or if health concerns or other hazards exist. |
||||
![]() |
8.6 | INTERIOR ROOM DOORS Moisture damage noted at master bathroom door; repair as needed.
|
||||
![]() |
8.7 | DETECTOR ALARM Although not required when the home was built, recommend adding carbon monoxide detectors as
appropriate. Smoke and carbon monoxide detectors should be tested upon moving in to home.
|
||||
![]() |
8.8 | THERMAL IMAGING A scan of the exterior walls and ceiling below the attic was performed using a thermal imaging camera.
Thermal imaging indicates insulation deficiencies in the attic at the ceiling joists and around the sky light
enclosures. This was confirmed with a visual examination of the attic and insulation levels. Add insulation
as needed for reduced energy loss.
|
||||
![]() |
8.9 | FIREPLACE The fireplace was operational. However, a heavy amount of creosote and debris fell out of the flue when
the damper was opened. The gas logs also need to be stacked according to the manufactures specs for
proper performance and life span. This is not something that can be determined during the inspection.
Recommend a qualified chimney sweep clean the unit and chimney and inspect for safety. |
||||
S | F | P | NA | NI | S= Satisfactory, F= Fair, P= Poor, NA= Not Applicable, NI= Not Inspected |
![]() 8.2 FLOORS (FRAMED) (Picture 1) sloping
|
![]() 8.3 STAIRS (Picture 1) height irregularity
|
![]() 8.5 REPRESENTATIVE WINDOWS (Picture 1) won't lock
|
![]() 8.5 REPRESENTATIVE WINDOWS (Picture 2) location
|
![]() 8.6 INTERIOR ROOM DOORS (Picture 1) moisture damage
|
![]() 8.7 DETECTOR ALARM (Picture 1) no co detection
|
![]() 8.8 THERMAL IMAGING (Picture 1) missing insulation
|
![]() 8.8 THERMAL IMAGING (Picture 2) cool spots
|
![]() 8.8 THERMAL IMAGING (Picture 3) cool spots
|
![]() 8.8 THERMAL IMAGING (Picture 4) skylight
|
![]() 8.8 THERMAL IMAGING (Picture 5) wall hatch
|
![]() 8.8 THERMAL IMAGING (Picture 6) ceiling hatch
|
![]() 8.8 THERMAL IMAGING (Picture 7) cool spots
|
![]() 8.8 THERMAL IMAGING (Picture 8) cool spots
|
(c) Copyright 2001 - 2025 HouseMaster | Each HouseMaster Franchise is an Independently Owned and Operated Business. |
![]() |
![]() Report ID: 24112213 / Buyer |
CONSTRUCTION TYPE: Crawlspace w/ Under House Garage |
CRAWLSPACE AREAS: Style: Fully Enclosed Location: Under Left Side Inspec. Method: Entered |
FOUNDATION WALLS/PIERS: Block Walls |
FLOOR STRUCTURE: Floor Framing: Wood Joists Beams: Solid and Built-up Wood Beam Support: Metal Columns Beam Support: Stud-Wall Beam support: Concrete Blocks |
INSULATION/VAPOR RETARDERS: Insulation betw. Joists: Fiber Batts (est. 2-3 inches) |
SPECIAL LIMITATIONS: Insulation |
S | F | P | NA | NI | ||
![]() |
9.0 | FOUNDATION WALLS Settlement noted. This is typical of older construction; however, no engineering evaluation was performed
to confirm acceptability of conditions. Repair as needed.
|
||||
![]() |
9.1 | PIERS / COLUMNS | ||||
![]() |
9.2 | FLOOR FRAMING Noted most areas could not be observed due to insulation. Hidden damage from moisture or other
conditions is possible, particularly below bathrooms and kitchens. Monitor and repair as needed.
|
||||
![]() |
9.3 | MAIN BEAM(S) | ||||
![]() |
9.4 | STAIRS / RAILINGS The handrail is loose/not secured to a wall stud; repair as needed. Although perhaps not required when
the house was built, stair height is low, should be 6'8" clearance on step to ceiling; monitor and repair as
needed.
The handrail should return to the guard to prevent possible snags and injury; repair as needed. |
||||
![]() |
9.5 | CRAWLSPACE VENTILATION PROVISIONS Opinions vary on whether or not your crawlspace should be ventilated if no moisture concerns exist. If
there is evidence of moisture then ventilation is required. Not opening the vents when moisture is present
could harm the floor system or contribute to mold. A dry crawlspace that is prepared for sealed design
considerations (special steps required) would not normally need venting but must be monitored..
Recommend repair or replace as needed using a qualified person.
|
||||
![]() |
9.6 | INSULATION Noted insulation has fallen in several areas; repair as needed.
|
||||
S | F | P | NA | NI | S= Satisfactory, F= Fair, P= Poor, NA= Not Applicable, NI= Not Inspected |
![]() 9.4 STAIRS / RAILINGS (Picture 1) low clearance
|
![]() 9.4 STAIRS / RAILINGS (Picture 2) no return
|
![]() 9.5 CRAWLSPACE VENTILATION PROVISIONS (Picture 1) blocked vent
|
![]() 9.5 CRAWLSPACE VENTILATION PROVISIONS (Picture 2) blocked vent
|
![]() 9.6 INSULATION (Picture 1) fallen insulation
|
(c) Copyright 2001 - 2025 HouseMaster | Each HouseMaster Franchise is an Independently Owned and Operated Business. |
![]() |
![]() Report ID: 24112213 / Buyer |
AREAS AT GRADE/SUBGRADE: Crawlspace Garage |
S | F | P | NA | NI | ||
![]() |
10.0 | EXTERIOR FEATURES / WATER INTRUSION FACTORS Monitor the house perimeter during heavy rains and make any necessary corrections. Maintain
drainage away from the foundation at all points. Include attention to minor details in any future
landscaping changes.
Any low and level areas next to the foundation could be a potential source of water accumulation at the exterior foundation areas. Monitor and regrade as/if needed to slope drainage away from the foundation and discharge the downspouts as far away from the house as possible. Poor exterior water management is the leading cause of frost action against the foundation walls. Frost action or soil expansion can lead to foundation movement. Keep all gutters clean and well adjusted. Keep downspouts attached and depositing water well away from the foundation. As needed, adjust surface slope to drain away from the foundation for at least six feet. |
||||
![]() |
10.1 | INTERIOR CONDITIONS / SIGNS OF WATER INTRUSION Visible signs of water intrusion in crawlspace are present from efflorescence on concrete blocks. Water
intrusion can cause deterioration and excessive moisture on building components if not corrected. See
note 2.3 and 2.4, sloping the ground or trenching may be needed to redirect water.
|
||||
S | F | P | NA | NI | S= Satisfactory, F= Fair, P= Poor, NA= Not Applicable, NI= Not Inspected |
![]() 10.1 INTERIOR CONDITIONS / SIGNS OF WATER INTRUSION (Picture 1) efflorescence
|
(c) Copyright 2001 - 2025 HouseMaster | Each HouseMaster Franchise is an Independently Owned and Operated Business. |
![]() |
![]() Report ID: 24112213 / Buyer |
![]() condenser unit |
TYPE SYSTEM: Electric Central Air Conditioning |
BRAND: Carrier |
SYSTEM LOCATION: Garage |
ESTIMATED AGE: 6 to 8 Years |
DESIGN LIFE: 8 to 10 years |
GENERAL DISTRIBUTION: Ducted System w/Room Supply Outlets |
SPECIAL LIMITATIONS: Cold Weather |
S | F | P | NA | NI | ||
![]() |
11.0 | ------ COOLING 1 ------- | ||||
![]() |
11.1 | COOLING SYSTEM - 1 Not inspected, operating system when temperatures are below 65 degrees may damage the compressor.
|
||||
![]() |
11.2 | CONDENSATE PROVISIONS - 1 The condensate lines should be checked for proper flow regularly.
|
||||
![]() |
11.3 | DUCTWORK Uninsulated ductwork noted in unconditioned areas; all sections should be insulated and wrapped with a
vapor retarder.
|
||||
S | F | P | NA | NI | S= Satisfactory, F= Fair, P= Poor, NA= Not Applicable, NI= Not Inspected |
(c) Copyright 2001 - 2025 HouseMaster | Each HouseMaster Franchise is an Independently Owned and Operated Business. |
![]() |
![]() Report ID: 24112213 / Buyer |
![]() heating unit |
![]() heat check |
![]() heat check |
BRAND: Carrier |
TYPE SYSTEM: Natural Gas |
SYSTEM LOCATION: Garage |
ESTIMATED AGE: 6 to 8 Years |
DESIGN LIFE: 15 to 20 years |
GENERAL DISTRIBUTION: Ducted w/Registers |
S | F | P | NA | NI | ||
![]() |
12.0 | ------ HEATING SYSTEM 1 ------- | ||||
![]() |
12.1 | HEATING UNIT 1 Rated fair due to no evidence of recent service. Manufacturers recommend annual maintenance.
Recommend the system be evaluated and serviced by a qualified licensed HVAC technician to ensure
proper operation and efficiency. Inspector evaluations are usually restricted to the basic operation of
Gas furnaces. No heat gain, sizing, or design evaluations were performed. Thermostat calibration,
accuracy and adequacy of conditioned air distribution were not determined. The heat exchanger and
internal components are not visible for inspection.
|
||||
![]() |
12.2 | BURNER 1 Burners are functional, rated fair due to age
|
||||
![]() |
12.3 | FUEL LINE AT UNIT | ||||
![]() |
12.4 | VENT CONNECTOR 1 Because the larger BTU furnace is positioned above the lower BTU water heater, the inducer fan may not
properly vent harmful gasses from the home; recommend consulting with qualified contractor for remedial
needs and costs prior to closing.
|
||||
![]() |
12.5 | BLOWER 1 Rated fair due to age, monitor and repair as needed.
|
||||
![]() |
12.6 | DISTRIBUTION SYSTEM Humidifiers are high maintenance items and require regular cleaning and servicing. Testing of whole
system humidifier is outside of the scope of this inspection. These systems are intended to introduce
moisture to the air flow during system operation, particularly during the colder months where running the
heat tends to dry the air in the home. These components are supplemental to basic function of the heating
and cooling system. Confirm operation with an HVAC contractor.
|
||||
![]() |
12.7 | THERMOSTAT | ||||
S | F | P | NA | NI | S= Satisfactory, F= Fair, P= Poor, NA= Not Applicable, NI= Not Inspected |
![]() 12.4 VENT CONNECTOR 1 (Picture 1) vent connections
|
![]() 12.6 DISTRIBUTION SYSTEM (Picture 1) humidifier
|
(c) Copyright 2001 - 2025 HouseMaster | Each HouseMaster Franchise is an Independently Owned and Operated Business. |
![]() |
![]() Report ID: 24112213 / Buyer |
![]() distribution panel |
HOUSE SERVICE: Service Line: Overhead Est. Service Capacity: 120/240 Volts; 150 Amps Type Service Feeder: Aluminum Est. Feeder Capacity: 150 Amps |
DISTRIBUTION PANEL: Type: Circuit Breaker Panel Est. Capacity: 150 Amps Main Disconnect: 150 Amps Location: Garage |
PANEL CIRCUITS: 120 Volt Circuits: Copper Wire 240 Volt Circuits: Copper & Aluminum |
CIRCUIT-INTERRUPTERS: GFCI: In Panel GFCI: At Receptacle Outlets AFCI: None Observed |
S | F | P | NA | NI | ||
![]() |
13.0 | SERVICE / ENTRANCE LINE Noted service head has pulled away from the siding; recommend consulting a qualified electrcian for
repair needed.
Tree branches are close to or in contact with the overhead service line; the line is subject to damage and power interruption. Recommend contacting the electric company as they may be responsible for maintenance of the line. |
||||
![]() |
13.1 | SERVICE GROUNDING PROVISIONS | ||||
![]() |
13.2 | DISTRIBUTION PANEL Although not required when panel was installed, doubled neutral circuits noted. The National Electric
Code updated requirements with NEC 408.41 that only one conductor (wire) should be connected at
any fuse, breaker or panel lug. The connection of a neutral conductor and equipment-grounding
conductor in the same termination is also not recommended. Advise redistribution where warranted.
Have an electrcian determine need.
White hot wire at 20 amp breaker and undersized wire at 30 amp breaker labeled GFCI. |
||||
![]() |
13.3 | REPRESENTATIVE DEVICES
Light fixtures, ceiling fans, etc., are generally randomly checked to assess basic wiring conditions. Any
inoperative unit may be due to a defective fixture or bulb, connection to undetected switch or other
factors.
|
||||
![]() |
13.4 | WIRING / CONDUCTORS
Exposed wires noted in garage,.Wires should only be spliced together using approved wire nuts; splices
should be installed in a covered junction (splice) box. Exposed/taped splices are not proper. Recommend
a qualified electrician repair for safety.
|
||||
![]() |
13.5 | GROUND-FAULT CIRCUIT-INTERRUPTER TEST See notes 1.9 and 7.3
|
||||
![]() |
13.6 | ARC-FAULT CIRCUIT INTERRUPTER TEST | ||||
![]() |
13.7 | DRYER ENERGY SOURCE Three prong dryer connection noted. Many newer dryers use a 4 prong receptacle and some
manufacturers require 4 prong receptacle and in other cases the 4 prong wiring can be changed out for
a 3 wire chord. Updating the wiring may be needed when a new appliance is installed.
|
||||
S | F | P | NA | NI | S= Satisfactory, F= Fair, P= Poor, NA= Not Applicable, NI= Not Inspected |
![]() 13.0 SERVICE / ENTRANCE LINE (Picture 1) line in trees
|
![]() 13.0 SERVICE / ENTRANCE LINE (Picture 2) clamp is not secured
|
![]() 13.2 DISTRIBUTION PANEL (Picture 1) doubled circuit
|
![]() 13.2 DISTRIBUTION PANEL (Picture 2) white hot wire
|
![]() 13.2 DISTRIBUTION PANEL (Picture 3) doubled neutral
|
![]() 13.4 WIRING / CONDUCTORS (Picture 1) exposed wires
|
![]() 13.4 WIRING / CONDUCTORS (Picture 2) exposed wires
|
(c) Copyright 2001 - 2025 HouseMaster | Each HouseMaster Franchise is an Independently Owned and Operated Business. |
![]() |
![]() Report ID: 24112213 / Buyer |
![]() gas meter |
![]() PRV |
![]() water shut off |
WATER SUPPLY PIPING: Copper |
DRAIN/WASTE LINES: Plastic (PVC/ABS) |
LOCATION OF SHUT-OFFS: Water: At Meter Water: In Garage Gas: At Meter |
SPECIAL LIMITATIONS: Vacant House Limited visibility |
S | F | P | NA | NI | ||
![]() |
14.0 | WATER SUPPLY PIPING (1) Noted leaking pipe in garage with heavy oxidation. Recommend conditions be evaluated by a licensed
plumber to determine remedial action required and associated costs.
(2) The standpipe for the water service cut off valve is visible in the front yard, but the cover was not opened
to determine if the pipe was tipped or clogged. It is the property owner's responsibility to keep this shut
off valve accessible and functional. HouseMaster inspectors look for the presence of the stop box as a
matter of courtesy , but assumes no liability for its presence or functional condition. For further
information, please contact the local Water Company
(3) Recommend insulating pipes in unconditioned areas to prevent potential freeze concerns.
|
||||
![]() |
14.1 | WATER FLOW AT FIXTURES Water pressure can vary slightly depending on flow, however inspector noted high pressure at several
fixtures. Normal range of pressure is 40 - 60 PSI. Pressure was observed at 140 PSI from pressure
gauge. Water pressure greater than 80 PSI is considered excessive and can contribute to failure of
plumbing components and appliances. Recommend a plumber assess conditions; the pressure reducing
valve may need replacement or one may need to be added if not present.
|
||||
![]() |
14.2 | DRAIN / WASTE PIPING See note 6.2
|
||||
![]() |
14.3 | DRYER VENT Recommend checking dryer vent tubing and cleaning for safety prior to moving in.
|
||||
![]() |
14.4 | GAS PIPING Old, uncoated brass flexible gas connectors are potentially unsafe. The Consumer Products Safety
Commission recommends replacement of these connectors.
|
||||
S | F | P | NA | NI | S= Satisfactory, F= Fair, P= Poor, NA= Not Applicable, NI= Not Inspected |
![]() 14.0(1) WATER SUPPLY PIPING (Picture 1) leaking
|
![]() 14.0(3) WATER SUPPLY PIPING (Picture 1) insulation recommended
|
![]() 14.1 WATER FLOW AT FIXTURES (Picture 1) high pressure
|
![]() 14.4 GAS PIPING (Picture 1) brass connector
|
![]() 14.4 GAS PIPING (Picture 2) brass connector label
|
(c) Copyright 2001 - 2025 HouseMaster | Each HouseMaster Franchise is an Independently Owned and Operated Business. |
![]() |
![]() Report ID: 24112213 / Buyer |
![]() water heater |
![]() normal temp |
HOT WATER SUPPLY: Tank-type Unit |
ENERGY SOURCE/FUEL: Gas |
ESTIMATED AGE: 6 to 8 Years |
BRAND: Rheem |
ESTIMATED CAPACITY: 50 +/- Gallons |
DESIGN LIFE: 5 to 10 years |
LOCATION: Garage |
S | F | P | NA | NI | ||
![]() |
15.0 | ------ HOT WATER SYSTEM 1 ------ | ||||
![]() |
15.1 | WATER HEATER Noted expansion tank is mounted on its side, traditionally these are mounted vertically. Equipment should
be installed consistent with manufacturer specifications; monitor and repair as needed.
The water heater was functional at the time of inspection, but is nearing the end of normal design life; future life is indeterminate. Consider adding a home warranty for possible failure. |
||||
![]() |
15.2 | VENT CONNECTOR Because the larger BTU furnace is positioned above the lower BTU water heater, the inducer fan may not
properly vent harmful gasses from the home; recommend consulting with qualified contractor for remedial
needs and costs prior to closing.
|
||||
![]() |
15.3 | GAS / FUEL LINES AT UNIT | ||||
![]() |
15.4 | SAFETY VALVE PROVISIONS Noted part of the piping is threaded material. Most manufacture's state using copper or CPVC only for the
drain line; check manufacture specifications and repair as needed.
|
||||
S | F | P | NA | NI | S= Satisfactory, F= Fair, P= Poor, NA= Not Applicable, NI= Not Inspected |
![]() 15.1 WATER HEATER (Picture 1) tank on side
|
![]() 15.4 SAFETY VALVE PROVISIONS (Picture 1) threaded piping
|
(c) Copyright 2001 - 2025 HouseMaster | Each HouseMaster Franchise is an Independently Owned and Operated Business. |
![]() |
![]() Report ID: 24112213 / Buyer |
SYSTEM DESCRIPTION: Septic |
LAST REPORTED PUMPING DATE: Indeterminate |
S | F | P | NA | NI | ||
![]() |
16.0 | SEPTIC SYSTEM
Regardless of inspection findings, pumping and assessment of the system by a qualified specialist is
recommended prior to closing. It is generally recommended that these systems be checked and/or
pumped every 5-7 years.
|
||||
S | F | P | NA | NI | S= Satisfactory, F= Fair, P= Poor, NA= Not Applicable, NI= Not Inspected |
(c) Copyright 2001 - 2025 HouseMaster | Each HouseMaster Franchise is an Independently Owned and Operated Business. |
![]() |
![]() |
Report ID: 24112213 / Buyer | |
SUMMARY OF INSPECTOR COMMENTS | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
This Summary of Inspector Comments is only one section of the Inspection Report and is provided for guidance purposes only. This Summary is NOT A HOME INSPECTION REPORT and does not include information on all conditions or concerns associated with this home or property. The Inspection Report includes more detailed information on element ratings/conditions and associated information and must be read and considered in its entirety prior to making any conclusive purchase decisions or taking any other action. Any questionable issues should be discussed with the Inspector and/or Inspection Company.
Note: While listings in this Summary of Inspector Comments may serve as a guide to help prioritize remedial needs, the final decision regarding any action to be taken must be made by the client following consultation with the appropriate specialists or contractors. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1. EXTERIOR ELEMENTS
2. SITE ELEMENTS
3. ROOFING
4. GARAGE
5. ATTIC
6. Bathrooms
7. KITCHEN (MAIN)
8. INTERIOR ELEMENTS
11. COOLING SYSTEM
13. ELECTRIC SYSTEM
14. PLUMBING SYSTEM
16. PRIVATE SEWAGE SYSTEM
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
(c) Copyright 2001 - 2025 HouseMaster | Services provided by a locally owned and independently operated franchise company. |